Bertazzoni MAST486GGASXE User Manual Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
21
For the gas valve of dual burner the choke valve
is located on the valve body (fi g.20), the A screw
adjust the outer ring, the B screw adjust the inner
ring.
OVEN BURNER
Reinstall the oven door.
Set the oven temperature control knob to the MA-
XIMUM setting.
Close the oven door and operate the oven for at
least 10 minutes.
Set the knob to the MINIMUM setting .
Remove the knob.
With a slotted screwdriver turn the choking screw
(by-pass screw at the left side of the thermostat
bar) and, while observing the ame at the same
time through the bottom oven porthole, evalua-
te the consistency of the ame so it remains on
when switching quickly from MINIMUM to MAXI-
MUM setting.
Broiler burner: the broiler burner always opera-
tes at maximum, therefore no minimum adjust-
ment is required.
When gas conversion is complete, complete the
enclosed conversion label and place it
next to the rating label.