Bertazzoni FREE-STANDING COOKERS 90x60 type M9V User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
5
T
ABLE N°1:
Adaption to various types of gas
Burners
Gas type
Pressure (kPa)
Injector (mm)
Small Natural
1.00 0.90
3.85
Small
U-LPG
2.75 0.54 3.75
Medium
Natural
1.00 1.18 7.12
Medium
U-LPG
2.75 0.70 6.20
Large
Natural
1.00 1.55 12.0
Large
U-LPG
2.75 0.92 11.25
Wok
Natural
1.00 1.55 12.5
Wok
U-LPG
2.75 0.95 13.1
Oven Natural
1.00 1.50
10.8
Oven U-LPG
2.75 0.85
9.4
TABLE N°2:
Adaption to various types of gas
Burners
Gas type
Pressure (kPa)
Injector (mm)
Small Natural
1.00 0.90
3.85
Small
U-LPG
2.75 0.54 3.75
Medium
Natural
1.00 1.18 7.12
Medium
U-LPG
2.75 0.70 6.20
Large
Natural
1.00 1.55 12.0
Large
U-LPG
2.75 0.92 11.25
Wok
Natural
1.00 1.55 12.5
Wok
U-LPG
2.75 0.95 13.1
Oven Natural
1.00 1.80 16.0
Oven U-LPG
2.75 1.10 16.0
BURNER ADJUSTMENT
1)Primary air adjustment:
Oven burner adjustment: follow the instructions below to adjust the primary air for the over burner:
1) Remove the oven bottom.
2) Loosen the screw P and adjust the position X of the Venturi cone (Fig. 12) according to the measurements indicated in
table 3.
TABLE N°3: Burner primary air regulation (indicative)
BURNER
Type of gas
Oven (mm)
M6
Natural fully open
Universal LPG fully open
2) Burner "MINIMUM" adjustment:
Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:
1) Light the burner and set the knob to the MINIMUM position (small flame).
2) Remove the knob of the valve that is press fit on the rod of that valve.
3) If the cooker is not equipped with safety valves on the surface burners, insert a small slotted screwdriver into the hole
on the valve rod (Fig. 13) and turn the choke screw to the right or left until the burner flame is adjusted to minimum. If the
cooker is equipped with safety valves, the choke valve is not located in the rod hole, but on the valve body (see fig. 14).
4) Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.
Oven burner adjustment: follow the instructions below to adjust the minimum:
1) Light the burner setting the knob to the MAXIMUM position.
2) Close the oven door and operate the oven for at least 10 minutes.
3) Set the knob to the MINIMUM position (corresponding to 120°) and then remove it.
Page view 4